經(jīng)銷品牌
你的位置:首頁(yè) » 產(chǎn)品中心 » Former(二手)儀器 » 網(wǎng)絡(luò)分析儀 » E8363C PNA Microwave Network Analyzer--手機(jī)18912657535
儀器名稱: E8363C PNA Microwave Network Analyzer--手機(jī)18912657535 儀器型號(hào): E8363C 40 GHz 2port 儀器品牌: Agilent 儀器指標(biāo): 10 MHz to 40 GHz
Key Features & Specifications
- 10 MHz to 40 GHz
- 110 dB of dynamic range <0.006 dB trace noise
- <26 usec/point measurement speed, 32 channels, 20,001 points
- TRL/LRM calibration, on-wafer, in-fixture, waveguide, and antenna measurements
- Mixer conversion loss, return loss, isolation, and absolute group delay
- Amplifier gain compression, harmonic, IMD, and pulsed-RF
Description
General-purpose network analysis with optional software and/or hardware to customize for your application - such as multiport, pulsed-RF, etc.
Option configurations
To add options to a product, order the corresponding item number.
Description
For E8362C For E8363C For E8364C For E8361C Additional
information
Test set
Option 014 Configurable test set E8362C-014 E8363C-014 E8364C-014 E8361C-014
Power configuration
Option UNL Extended power range E8362C-UNL E8363C-UNL E8364C-UNL E8361C-UNL Only E8361C requires 014 and bias-tees
Option 016 Add receiver attenuators E8362C-016 E8363C-016 E8364C-016 E8361C-016 Requires UNL (only E8361C also requires 014)
Option H851 High-power configuration E8362CH85 E8363CH85 E8364CH85 Includes 014, 016, UNL2, 080, 081
Measurement applications
Option 010 Time-domain capability E8362C-010 E8363C-010 E8364C-010 E8361C-010
Option 080 Frequency offset E8362C-080 E8363C-080 E8364C-080 E8361C-080 Requires 014 (E8361C only, 081 required
if UNL is also purchased)
Option 081 Reference receiver switch E8362C-081 E8363C-081 E8364C-081 E8361C-081 Requires 014, 080 (only E8361C also requires UNL)
Option 082 Scalar-calibrated E8362C-082 E8363C-082 E8364C-082 E8361C-082 Requires 014, 080
converter measurements
Option 083 Vector- and scalar-calibrated E8362C-083 E8363C-083 E8364C-083 E8361C-083 Requires 014, 080, 081(only E8361C
converter measurements
also requires UNL)
Option 0843 Embedded LO measurements E8362C-084 E8363C-084 E8364C-084 E8361C-084 Requires 082 or 083
Option 5504 4-port measurement application E8362C-550 E8363C-550 E8364C-550 E8361C-550 Requires 014
Option 5514 N-port capabilities E8362C-551 E8363C-551 E8364C-551 E8361C-551 Requires 014
Pulse, antenna, mm-wave
Option H08 Pulsed-RF measurement E8362C-H08 E8363C-H08 E8364C-H08 E8361C-H08 Requires 014, 080 (Option H11
capability recommended)
Option H11 IF access (for antenna, E8362C-H11 E8363C-H11 E8364C-H11 E8361C-H11 Requires 014, UNL, 080, and 081
pulsed-RF and mm-
wave
measurements)
Accessories
Option 1CM Rack mount kit for use E8362C-1CM E8363C-1CM E8364C-1CM E8361C-1CM
without handles
Option 1CP Rack mount kit for use E8362C-1CP E8363C-1CP E8364C-1CP E8361C-1CP
with handles
Calibration documentation
Option 1A7 ISO 17025 compliant E8362C-1A7 E8363C-1A7 E8364C-1A7 E8361C-1A7
calibration
Option UK6 Commercial calibration E8362C-UK6 E8363C-UK6 E8364C-UK6 E8361C-UK6
certificate with test data
Option A6J ANSI Z540 compliant E8362C-A6J E8363C-A6J E8364C-A6J E8361C-A6J
calibration
Calibration software for self-maintainers
Option 8975 Perpetual license of built-in E8362C-897 E8363C-897 E8364C-897 E8361C-897
performance test software for Agilent exclusive calibration
Option 8985 Perpetual license of built-in E8362C-898 E8363C-898 E8364C-898 E8361C-898
performance test software for standards compliant calibration
To add options to a product, order the corresponding item number.
Description
For E8362C For E8363C For E8364C For E8361C Additional
information
Test set
Option 014 Configurable test set E8362C-014 E8363C-014 E8364C-014 E8361C-014
Power configuration
Option UNL Extended power range E8362C-UNL E8363C-UNL E8364C-UNL E8361C-UNL Only E8361C requires 014 and bias-tees
Option 016 Add receiver attenuators E8362C-016 E8363C-016 E8364C-016 E8361C-016 Requires UNL (only E8361C also requires 014)
Option H851 High-power configuration E8362CH85 E8363CH85 E8364CH85 Includes 014, 016, UNL2, 080, 081
Measurement applications
Option 010 Time-domain capability E8362C-010 E8363C-010 E8364C-010 E8361C-010
Option 080 Frequency offset E8362C-080 E8363C-080 E8364C-080 E8361C-080 Requires 014 (E8361C only, 081 required
if UNL is also purchased)
Option 081 Reference receiver switch E8362C-081 E8363C-081 E8364C-081 E8361C-081 Requires 014, 080 (only E8361C also requires UNL)
Option 082 Scalar-calibrated E8362C-082 E8363C-082 E8364C-082 E8361C-082 Requires 014, 080
converter measurements
Option 083 Vector- and scalar-calibrated E8362C-083 E8363C-083 E8364C-083 E8361C-083 Requires 014, 080, 081(only E8361C
converter measurements
also requires UNL)
Option 0843 Embedded LO measurements E8362C-084 E8363C-084 E8364C-084 E8361C-084 Requires 082 or 083
Option 5504 4-port measurement application E8362C-550 E8363C-550 E8364C-550 E8361C-550 Requires 014
Option 5514 N-port capabilities E8362C-551 E8363C-551 E8364C-551 E8361C-551 Requires 014
Pulse, antenna, mm-wave
Option H08 Pulsed-RF measurement E8362C-H08 E8363C-H08 E8364C-H08 E8361C-H08 Requires 014, 080 (Option H11
capability recommended)
Option H11 IF access (for antenna, E8362C-H11 E8363C-H11 E8364C-H11 E8361C-H11 Requires 014, UNL, 080, and 081
pulsed-RF and mm-
wave
measurements)
Accessories
Option 1CM Rack mount kit for use E8362C-1CM E8363C-1CM E8364C-1CM E8361C-1CM
without handles
Option 1CP Rack mount kit for use E8362C-1CP E8363C-1CP E8364C-1CP E8361C-1CP
with handles
Calibration documentation
Option 1A7 ISO 17025 compliant E8362C-1A7 E8363C-1A7 E8364C-1A7 E8361C-1A7
calibration
Option UK6 Commercial calibration E8362C-UK6 E8363C-UK6 E8364C-UK6 E8361C-UK6
certificate with test data
Option A6J ANSI Z540 compliant E8362C-A6J E8363C-A6J E8364C-A6J E8361C-A6J
calibration
Calibration software for self-maintainers
Option 8975 Perpetual license of built-in E8362C-897 E8363C-897 E8364C-897 E8361C-897
performance test software for Agilent exclusive calibration
Option 8985 Perpetual license of built-in E8362C-898 E8363C-898 E8364C-898 E8361C-898
performance test software for standards compliant calibration